Best Fittings One Way Valve Foster QD Coupler Compressor Connector Male-Male
The BEST Fittings One-Way Valve Quick Coupler Compressor Connector is an inline male-male quick coupler with an integrated one-way valve, designed for use with small electric 300 bar compressors, including the HILL EVO 310 and UMAREX, Bisley, GX, Tuxing and WULF box compressors, along with other suitable high-pressure compressor systems.
It helps prevent high-pressure air from travelling backwards through the filling hose and into the compressor when the cylinder valve is opened before the compressor has built up line pressure.
Yes, we know you do it. We also know because we sell a frankly unreasonable number of replacement burst discs. If you regularly forget to let the filling line pressurise before opening the bottle valve, this is exactly the sort of fitting you should probably have in the system.
What Does the One-Way Valve Do?
When filling a cylinder, the pressure inside the cylinder can be significantly higher than the pressure in the compressor and filling line.
Without a non-return valve, opening the cylinder valve too early can allow that high-pressure air to rush backwards through the filling line towards the compressor. On suitable compressors, this can contribute to problems such as burst-disc failure.
The BEST Fittings one-way valve prevents that reverse flow.
Once the compressor pressure reaches the pressure already present in the cylinder, the valve opens automatically and allows the compressor to continue filling the cylinder normally.
This means you can open the cylinder valve before starting the compressor rather than having to build line pressure first.
Inline Installation
The male-male configuration is designed to be fitted directly inline in the filling hose between the compressor and the cylinder.
The fitting has a marked flow direction. The arrow must point towards the cylinder being filled.
If you are using an inline dry pack/filter, install the one-way valve after the filter. This allows the air to pass through the drying filter before reaching the non-return valve and ultimately the cylinder.
The order should therefore be:
Compressor → Dry Pack/Filter → One-Way Valve → Cylinder
Using the Connector
- Install the connector inline between the compressor and cylinder.
- Check that the flow arrow points towards the cylinder.
- Ensure all bleed valves are closed.
- Slowly open the cylinder valve.
- Start the compressor according to the manufacturer's instructions.
- The one-way valve prevents cylinder pressure from travelling backwards towards the compressor.
- Once compressor pressure reaches cylinder pressure, the valve opens automatically and filling continues.
- When the cylinder is full, close the cylinder valve.
- Bleed both sides of the fitting before disconnecting.
Always follow the manufacturer's instructions for your compressor, cylinder and filling equipment, including their specified pressure limits.
Features
- Integrated one-way / non-return valve
- Male-male quick coupler configuration
- Designed for inline installation
- Prevents cylinder pressure travelling back towards the compressor
- Allows cylinder valve to be opened before starting the compressor
- Automatically opens once compressor pressure catches up
- Suitable for small electric 300 bar compressors
- Compatible with HILL EVO 310 and UMAREX, Bisley, GX, Tuxing and WULF box compressors
- Compatible with inline dry packs when installed after the filter
- Helps reduce the risk of compressor burst-disc failure caused by back pressure
Specifications
- Product: BEST Fittings One-Way Valve Quick Coupler
- Configuration: Male-male
- Type: Inline quick coupler with one-way valve
- Function: Non-return / one-way valve
- Application: High-pressure compressor filling systems
- Intended system pressure: Up to 300 bar
- Flow direction: Towards cylinder
- Installation position: Between compressor and cylinder
- Compatible equipment: HILL EVO 310 and suitable UMAREX, Bisley, GX, Tuxing and WULF box compressors
Important: This fitting is designed to manage reverse pressure within a suitable high-pressure filling system. It does not replace the manufacturer's filling procedure or safety equipment. Always use compatible components with appropriate pressure ratings and fully bleed the system before disconnecting high-pressure connections.